RIGOL 2 Command System
2-102 MSO2000A/DS2000A Programming Guide
:FUNCtion:WREPlay:TTAG
Syntax
:FUNCtion:WREPlay:TTAG <bool>
:FUNCtion:WREPlay:TTAG?
Description
Enable or disable the time tag in waveform playback; or query the current status of the time tag in
waveform playback.
Parameter
Name Type Range Default
<bool> Bool {{0|OFF}|{1|ON}} 0|OFF
Return Format
The query returns 0 or 1.
:FUNCtion:WREPlay:CTAG?
Syntax
:FUNCtion:WREPlay:CTAG?
Description
Query the record time difference of the waveform currently displayed relative to the first frame of
waveform.
Return Format
The query returns the record time difference in scientific notation.