2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-203
:MEASure:MPARea:SMAXimum?
:MEASure:MPARea:SMINimum?
:MEASure:MPARea:SCURrent?
:MEASure:MPARea:SAVerage?
:MEASure:MPARea:SDEViation?
Syntax 1
:MEASure:MPARea:SMAXimum <chan>
:MEASure:MPARea:SMINimum <chan>
:MEASure:MPARea:SCURrent <chan>
:MEASure:MPARea:SAVerage <chan>
:MEASure:MPARea:SDEViation <chan>
Description 1
Enable the period area measurement function of the specified channel and enable the statistic function.
Syntax 2
:MEASure:MPARea:SMAXimum? <chan>
:MEASure:MPARea:SMINimum? <chan>
:MEASure:MPARea:SCURrent? <chan>
:MEASure:MPARea:SAVerage? <chan>
:MEASure:MPARea:SDEViation? <chan>
Description 2
Enable the period area measurement function of the specified channel; enable the statistic function;
return the maximum value, minimum value, current value, average value or standard deviation.
Parameter
Name
Type Range Default
<chan> Discrete {CHANnel1|CHANnel2|MATH} --
Return Format
The query returns the measurement result in scientific notation.

Table of Contents

Other manuals for Rigol MSO2000A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol MSO2000A Series and is the answer not in the manual?

Rigol MSO2000A Series Specifications

General IconGeneral
BrandRigol
ModelMSO2000A Series
CategoryTest Equipment
LanguageEnglish

Related product manuals