RIGOL 2 Command System
2-302 MSO2000A/DS2000A Programming Guide
:TRIGger:RUNT:WUPPer
Syntax
:TRIGger:RUNT:WUPPer <NR3>
:TRIGger:RUNT:WUPPer?
Description
Set or query the upper limit of the pulse width in runt trigger.
Parameter
Name Type Range Default
<NR3> Discrete
When the qualifier is <: 2ns to 4s
When the qualifier is <>: 10ns to 4s
2us
Return Format
The query returns the upper limit of the pulse width in scientific notation.