RIGOL 2 Command System
2-308 MSO2000A/DS2000A Programming Guide
:TRIGger:SLOPe:TLOWer
Syntax
:TRIGger:SLOPe:TLOWer <time>
:TRIGger:SLOPe:TLOWer?
Description
Set or query the lower limit of time in slope trigger. The unit is s.
Parameter
Name Type Range Default
<time> Real
or : 10ns to 1s
or : 10ns to 999ms
1us
Explanation
This command is only available when the trigger condition (refer to the
:TRIGger:SLOPe:WHEN command)
is PGReater, NGReater, PGLess or NGLess.
Return Format
The query returns the lower limit of time in scientific notation.
:TRIGger:SLOPe:TUPPer
Syntax
:TRIGger:SLOPe:TUPPer <time>
:TRIGger:SLOPe:TUPPer?
Description
Set or query the upper limit of time in slope trigger. The unit is s.
Parameter
Name Type Range Default
<time> Real
or : 10ns to 1s
or : 20ns to 1s
2us
Explanation
This command is only available when the trigger condition (refer to the
:TRIGger:SLOPe:WHEN command)
is PLESs, NLESs, PGLess or NGLess.
Return Format
The query returns the upper limit of time in scientific notation.

Table of Contents

Other manuals for Rigol MSO2000A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol MSO2000A Series and is the answer not in the manual?

Rigol MSO2000A Series Specifications

General IconGeneral
BrandRigol
ModelMSO2000A Series
CategoryTest Equipment
LanguageEnglish

Related product manuals