2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-311
:TRIGger:SLOPe:WINDow
Syntax
:TRIGger:SLOPe:WINDow <window>
:TRIGger:SLOPe:WINDow?
Description
Set or query the vertical window type in slope trigger.
Parameter
Name Type Range Default
<window> Discrete {TA|TB|TAB} TA
Explanation
Different vertical windows correspond to different trigger level adjustment modes.
TA: only adjust the upper limit of the trigger level.
TB: only adjust the lower limit of the trigger level.
TAB: adjust the upper and lower limits of the trigger level at the same time.
Return Format
The query returns TA, TB or TAB.