Page 39
System: Controls
Parameter
Default
NO: Causes the following parameters to function as follows:
Auto Arm Bypass: If the Auto Arm programming arms the system and there is an
open zone during the Auto Arm, the system will bypass the open zones and arm
the system
A utility output defined as “Auto Arm Alarm” is deactivated
A utility output defined as “Zone Loss Alarm” is deactivated
Bypass Unique Code NO
YES: Unique code for the purpose of the Door Bypass feature. The codes used for the
Door Bypass feature are defined with Door Bypass authority level.
NO: The regular user code can be used as a bypass code (not including Arm only
authority level). The same user codes will be used from a bypass keypad and from a
regular keypad
Silent Remote Install
YES: During Configuration Software programming, all panel sounds are suppressed.
NO: The panel generates sounds during Configuration Software programming.
Anti Mask = Tamper
NO
Used to determine the operation of Anti Masking detection in wirelss detectors
YES:. Anti mask violation will activate tamper alarm
NO: Anti mask violation will be regarded as trouble event
Power Management
NO
Used for improved power managmant of the system.
YES: When lost od AC power is detected, the communcaiton to the cloud will be
disconncted. Connection to the cloud wil be established once AC is back
NO: Connction to the cloud will no tbe affected by the AC power status.
Presence Log
NO
YES: Presence will be recorded in the event log.
NO: Presence will not be recorded in the event log.
Secondary Alarm
NO
YES: If smoke or heat is detected by one of the Smoke, Heat and PIR detectors in the
system, the other Smoke, Heat and PIR detectors in the system will sound their sirens.
NO: If smoke or heat is detected by one of the Smoke, Heat and PIR detectors in the
system, the other Smoke, Heat and PIR detectors in the system will not sound their sirens.
Note: This option applies only to the RWX35SP Smoke, Heat and PIR detector.