Page 42
System: Controls
Parameter
Default
Attenuation
NO
YES: The WiComm Pro receiver will be attenuated by 6 dB during the communication
test.
NO: The WiComm Pro receiver works in normal operation mode.
DD243 programming
Bypass Exit/Entry
YES
YES: It is possible for the user to bypass an Exit/Entry zone.
NO: An Exit/Entry zone cannot be bypassed.
Entry Disable
NO
YES: The alarm confirmation process will be disabled when the entry time starts.
NO: The alarm confirmation process will start when the entry time starts.
Route Disable
NO
YES: The panel disables the entry route zones (EX/EN, EX (OP)/EN, followers and Final
Exit) from participating in the alarm confirmation process when the entry time starts.
Note: Sequential confirmation can still be established from two confirmed zones, located off the entry route.
NO: The entry route zones will participate in the alarm confirmation process when the
entry time starts.
Installer Reset Confirmation
NO
YES: An installer reset confirmation is required in order to reset the system after a
confirmed alarm. The system cannot be armed until an Installer Reset Confirmation is
performed. The reset can be done by entering the Anti code, by entering the installation
mode, or by performing an installer reset” from the keypad.
NO: Any means can be used to arm or disarm the system (keypad, remote phone
operation, etc.).
Key Switch Lock
NO
YES: Only a latched Key Switch zone can arm or disarm the system.
Note: When the system has more than 1 zone defined as Latch Key Switch, the arm/disarm operation will
occur only after all these zones are armed or disarmed.
NO: Any means can be used to arm or disarm the system (keypad, remote phone
operation, etc.).