YES: The user must confirm that he/she is aware that alarm occurred in the system
before rearming the system. The system will be in "Not Ready" status until the user
confirms the alarm. This is done via the User menu > Activities > Advanced > Restore
Alarm.
NO: The user does not need to confirm the alarm before rearming the system.
YES: Only mandatory events (specified in the EN standard) will be displayed in the
Event Log.
NO: All the events will be displayed in the Event Log.
YES: The user must manually confirm the restoral of each trouble to a normal condition.
This is done via the User menu > Activities > Advanced > Restore Troubles.
NO: The restoral report of each trouble is automatic.
YES: A violated zone outside the exit route will generate an alarm during the exit time. A
report to the monitoring station for arming the system is sent at the beginning of the
arming procedure.
NO: A violated zone outside the exit route will cancel the arming process. A report to the
monitoring station is send at the end of a successful arming procedure.
This feature is used to reduce false alarm reports to the Monitoring Station.
YES: The report to the monitoring station and the siren alarm will be delayed for 30
seconds or until the end of the predefined entry delay (the shorter time of the two)
following a violation of a zone outside the entry route.
NO: A violated zone outside the entry route will generate an alarm during the
entry time and a report will be sent to the monitoring station.
YES: Prior to arming the system, the system will check for zones that did not send a
signal for more than 20 minutes. These zones will be regarded as not ready. A partition
assigned with a not ready zone cannot be armed.
NO: Prior to arming, the system will not check whether a zone did not send a signal for
more than 20 minutes.