Method: GSM
Parameter
Default
Range
Timers
Allows to program timers related to operation with the GSM module
GSM Lost
10 min
001-255 min
The time after which the GSM module regards the GSM network as loss.
Network loss is defined as RSSI level below the level defined GSM Network
Sensitivity parameter.
SIM Expire
00
00-36 months
A prepaid SIM card has a defined life length defined by the provider. After each
charging of the SIM, the user will have to manually reset the expiration time of
the SIM card. A notification will be displayed on the wireless keypad when
asking for status indication.
Set the SIM expiring date (in months) using the numeric keys, according to the
time given by the provider.
MS Keep Alive (Polling)
02160
0-65535 times
The time period that the system will establish automatic communication
(polling) with the MS over GPRS, in order to check the connection.
3 polling times can be defined: Primary, Secondary and Backup. For each time
period define the number of units between 1- 65535. Each unit represents a time
frame of 10 seconds.
Note: When using the polling feature through GPRS the MS channel parameter must be defined
as GPRS only.
The report code for MS polling is 999 (Contact ID) or ZZ (SIA)
The use of these time periods depends on the reporting order to the MS defined
by the Report Split MS Urgent parameter (See: [4]Communication > [2]MS >
[7]Report Split)
Primary: This time period is used when the MS channel is defined as GPRS
Only and the Report Split parameter is not defined as 1
st
backup 2
nd
Secondary: This time period is used when the MS 2 channel is defined as
IP>GPRS Only and the Report Split parameter is defined as 1
st
backup 2
nd
Backup: This time period will be assigned to the backup channel in the
following case:
MS 2 channel is defined as IP>GPRS Only
Report Split parameter is defined as 1
st
backup 2
nd
The communication with MS 1 is disconnected