Press the WPS button on the router to establish a connection and then press the
WPS button on the panel within 2 min.
A “Successfully Connected” to network message will appear.
The time period that the system will establish automatic communication (polling) with
the MS over the IP network, in order to check the connection. 3 polling times can be
defined: Primary, Secondary and Backup. For each time period define the number of
units between 1- 65535. Each unit represents a time frame of 10 seconds.
Note: When using the polling feature through IP, the MS channel parameter must be defined as IP only.
The use of these time periods depends on the reporting order to the MS defined by the
Report Split MS Urgent parameter (See: [4]Communication > [2]MS > [7]Report Split)
⬧ Primary: This time period is used when the MS channel is defined as IP Only and the
Report Split parameter is not defined as 1
st
backup 2
nd
. Default: 00003 (30 seconds).
⬧ Secondary: This time period is used when the MS 2 channel is defined as IP>IP Only
and the Report Split parameter is defined as 1
st
backup 2
nd
. Default: 360 (3600 seconds).
⬧ Backup: This time period will be assigned to the backup channel in the following case:
MS 2 channel is defined as IP>IP Only
Report Split parameter is defined as 1
st
backup 2
nd