Parameters:
<Direction> INPut
Port works as an input.
OUTPut
Port works as an output.
*RST: INPut
Manual operation: See "Trigger 2/3" on page 383
OUTPut:TRIGger<port>:LEVel <Level>
This command defines the level of the signal generated at the trigger output.
This command works only if you have selected a user defined output with OUTPut:
TRIGger<port>:OTYPe.
Suffix:
<port>
.
Selects the trigger port to which the output is sent.
2 = trigger port 2 (front)
3 = trigger port 3 (rear)
Parameters:
<Level> HIGH
TTL signal.
LOW
0 V
*RST: LOW
Manual operation: See "Trigger 2/3" on page 383
See "Level" on page 384
OUTPut:TRIGger<port>:OTYPe <OutputType>
This command selects the type of signal generated at the trigger output.
Suffix:
<port>
.
Selects the trigger port to which the output is sent.
2 = trigger port 2 (front)
3 = trigger port 3 (rear)
Setting Basic Measurement Parameters