Remote Commands
R&S
®
FSW
944User Manual 1173.9411.02 ─ 19
Example:
INIT:CONT OFF
Switches to single measurement mode.
CALC:MARK2 ON
Switches marker 2.
INIT;*WAI
Starts a measurement and waits for the end.
CALC:MARK2:Y?
Outputs the measured value of marker 2.
Usage: Query only
Manual operation: See "Marker Table" on page 441
See "Marker Peak List" on page 441
11.8.3.6
Marker Search (Spectrograms)
The following commands automatically define the marker and delta marker position in
the spectrogram.
The usage of these markers is demonstrated in chapter 11.8.2.6, "Programming Exam-
ple: Configuring a Spectrogram", on page 925.
Using Markers
The following commands control spectrogram markers.
Useful commands for spectrogram markers described elsewhere
The following commands define the horizontal position of the markers.
● CALCulate<n>:MARKer<m>:MAXimum:LEFT on page 937
● CALCulate<n>:MARKer<m>:MAXimum:NEXT on page 937
● CALCulate<n>:MARKer<m>:MAXimum[:PEAK] on page 938
● CALCulate<n>:MARKer<m>:MAXimum:RIGHt on page 938
● CALCulate<n>:MARKer<m>:MINimum:LEFT on page 938
● CALCulate<n>:MARKer<m>:MINimum:NEXT on page 939
● CALCulate<n>:MARKer<m>:MINimum[:PEAK] on page 939
● CALCulate<n>:MARKer<m>:MINimum:RIGHt on page 939
Remote commands exclusive to spectrogram markers
CALCulate<n>:MARKer<m>:SGRam|SPECtrogram:FRAMe.............................................. 945
CALCulate<n>:MARKer:SGRam|SPECtrogram:SARea..................................................... 945
CALCulate<n>:MARKer<m>:SGRam|SPECtrogram:XY:MAXimum[:PEAK]..........................945
CALCulate<n>:MARKer<m>:SGRam|SPECtrogram:XY:MINimum[:PEAK]...........................945
CALCulate<n>:MARKer<m>:SGRam|SPECtrogram:Y:MAXimum:ABOVe............................946
CALCulate<n>:MARKer<m>:SGRam|SPECtrogram:Y:MAXimum:BELow............................ 946
CALCulate<n>:MARKer<m>:SGRam|SPECtrogram:Y:MAXimum:NEXT..............................946
CALCulate<n>:MARKer<m>:SGRam|SPECtrogram:Y:MAXimum[:PEAK]............................946
Analyzing Measurements (Basics)