R&S®SML / R&S®SMV03 Stereo Modulation (Option R&S SML-B5)
1090.3123.12 4.29 E-6
EON-TP
Description: Enhanced Other Networks:
sets the TP flag for the EON with PI=yyyy.
Command: EON-TP=yyyy,x
Query: EON-TP,yyyy?
Response: x
Value range: x = 0|1
yyyy = 0000 to FFFF (ASCII coded hexadecimal numbers)
Example: Command:
STEReo:DIRect “EON-TP=1000,1“
Sets the TP flag for the EON with PI=1000 to "1".
Query:
STEReo:DIRect? “EON-TP,1000“
Reads the TP flag of the EON with PI=1000.
Response:
"1"
GS
Description: Sets or reads the group sequence.
Command: GS=xx,xx, ...,xx (1 to 36 groups)
Query: GS?
Response: xx,xx, ...,xx
Value range: xx = 2 or 3 characters: 0A,1A,2A, … to 15B
Example: Command:
STEReo:DIRect “GS=0A,1B,10A,15A“
The groups 0A,1B,10A,15A are transmitted.
Query:
STEReo:DIRect? “GS“
Response:
"0A,1B,10A,15A"
Note: Only group A or group B data may be sent at a time.
Only groups that contain data are transmitted.
The groups 4A, 14B and 15B are automatically added to the group sequence and must not
be added or removed manually.