Test setup for setting time R&S®SML / R&S®SMV03
1090.3123.12 10.4 E-6
Test setup for SSB phase noise
Test setup 3:
Measuring
equipment
- Test receiver
(table "Measuring Equipment and Accessories", item 1)
- Second test transmitter
(table "Measuring Equipment and Accessories", item 4)
- Phase noise tester consisting of
- Mixer with low pass filter and preamplifier
(table "Measuring Equipment and Accessories", item 5)
- Storage oscilloscope
(table "Measuring Equipment and Accessories", item 2)
Test setup
10 MHz reference
Oszilloskop
RF
Mixer
,
preamlifier
transmitter
Test setup for output reflection coefficient
Test setup 4:
Measuring
equipment
- Test receiver
(table "Measuring Equipment and Accessories", item 1)
- Second test transmitter
(table "Measuring Equipment and Accessories", item 4)
- VSWR bridge
(table "Measuring Equipment and Accessories", item 6)
Test setup
10 MHz reference
Source
Test port
Refl.
Bridge
RF
Test
receiver
transmitter
Note: The test port of the bridge must be screwed directly to the device
under test. The INPUT of the directional coupler is screwed to the
DUT. The second test transmitter is connected to the line
connector, and the analyzer to the coupling output (-13 dB) of the
directional coupler.