SOURce:PHASe R&S SML
1090.3123.12 E-6 6.24
SOURce:PHASe Subsystem
This subsystem contains the commands to adjust phase between the RF output signal and a reference
signal of the same frequency.
Command Parameters Default
Unit
Remark
[:SOURce]
:PHASe
-360 ... 360 DEG | UP | DOWN
DEG
:REFerence
:STATe
ON | OFF
:STEP -360 ... 360 DEG DEG
[:SOURce]:PHASe -360 to 360 DEG | UP | DOWN
Setting value of the phase of the output signal with respect to a reference signal of the same
frequency. Phase values from -360 ° to 360 ° are possible. Alternatively, the actual setting value
can be varied by UP or DOWN steps. The command [:SOURCE]:PHASe:STEP specifies the step
width. Step widths from -360 ° to 360 ° are possible.
Example: :SOUR:PHAS 40 DEG *RST value is 0 DEG
[:SOURce]:PHASe:REFerence
The command sets the phase value to 0. The phase of output signal will not be changed.
Example: :SOUR:PHAS:REF *RST value is 0
[:SOURce]:PHASe:STATe ON | OFF
Switching on/off phase setting.
Example: :SOUR:PHAS:STAT ON *RST value is OFF
[:SOURce]:PHASe:STEP -360 to 360 DEG
The command sets the step width for [:SOURce]:PHASe UP or [:SOURce]:PHASe DOWN. Step
widths from -360 ° to 360 ° are possible. Preset or *RST does not change the step width.
Example: :SOUR:PHAS:STEP 90 DEG