R&S®SML / R&S®SMV03 SOURce:MODulation
1090.3123.12 E-6 6.23
SOURce:MODulation Subsystem
Command Parameters Default
Unit
Remark
[:SOURce]
:MODulation
[:ALL]
STATe
ON | OFF
[:SOURce]:MODulation[:ALL]:STATe ON | OFF
This command deactivates all types of modulation with OFF. All analog, vector, digital, digital
standard and ARB modulations are thus set to OFF if they were switched on before. This
command can be used before switching on a new type of modulation in order to avoid the error
message "settings conflict" since only one type of modulation can be operated at the same time.
The modulation used last is activated again with ON (same function as MOD ON/OFF key).
This command triggers an event and hence has no *RST value and no query.
Example: :SOUR:MOD:STAT OFF