Status Reporting System R&S®SML / R&S®SMV03
1090.3123.12 E-6 5.24
Reset Values of Status Reporting System
Table 5-4 lists the commands and events that cause a reset of the status reporting system. Except for
*RST and SYSTem:PRESet, none of the commands has an effect on the functional settings of the
instrument. It should be noted in particular that DCL also does not change instrument settings.
Table 5-4 Resetting of instrument functions
Event
Switching on of
AC supply voltage
DCL, SDC
Power On Status
Clear
(Device Clear,
Selected Device
Clear)
*RS
T or
SYSTem:PRESet
STATus:PRESet *CLS
Effect 0 1
Clears STB, ESR
yes
yes
Clears SRE, ESE
yes
Clears PPE
yes
Clears EVENt parts of the
registers
yes
yes
Clears ENABle parts of all
OPERation and
QUESTionable registers,
fills ENABle parts of all
ot
her regi
sters with "1"
yes
yes
Fills PTRansition parts
with "1",
clears NTRansition parts
yes
yes
Clears error queue yes yes
yes
Clears output buffer yes yes yes 1) 1) 1)
Clears command
processing and input
buffer
yes yes yes
1) Each command which is the first in a command line, ie which directly follows the <PROGRAM MESSAGE TERMINATOR>, clears the output
buffer.