R&S®SML / R&S®SMV03 Test setup for setting time
1090.3123.12 10.5 E-6
Test setup for pulse modulator option R&S SML-B3
Test setup 5:
Measuring
equipment
- Storage oscilloscope
(table "Measuring Equipment and Accessories", item 2)
Test setup
RF
Ext. trigger
Oscilloscope
RF
Pulse/Video
Note: Since the input of the oscilloscope is high-impedance, the BNC
connection to the oscilloscope must be terminated into 50 Ohm via
a T-piece.
Test setup for stereo coder option R&S SML-B5
Test setup 6:
Measuring
equipment
- Modulation analyzer
(table "Measuring Equipment and Accessories", item 12)
- Audio analyzer
(table "Measuring Equipment and Accessories", item 13)
- RDS decoder
(table "Measuring Equipment and Accessories", item 14)
Test setup
Mod.
analyzer
RF_out
Audio
analyzer
Process
controller
RDS decoder
RF_in
Stereo_L,R
S/P DIF
L,R_out
AF_out
MPX_in
IEC/IEEE bus
Analog
Gen_out 1,2
Digital
Gen_out
Analyzer_in 1,2