Test sequence R&S®SML / R&S®SMV03
1090.3123.12 10.22 E-6
Spurious PhiM in AM
Test setup Test setup 1, demodulator mode
Settings on the R&S
SML01
- LEVEL: 2.1 dBm
with R&S SML-B10: 12.1 dBm
- FREQ:
77 MHz, 1100 MHz
- MODULATION AM AM DEPTH: 30 %
AM SOURCE: LFGen
LFGenFreq = 1 kHz
Settings on the R&S
SML02/03 / R&S SMV03
- LEVEL: 8 dBm
with R&S SML-B10: 18 dBm
- FREQ:
in addition to the test frequencies for R&S SML01:
2200 MHz, 3300 MHz
- MODULATION AM AM DEPTH: 30 %
AM SOURCE: LFGen
LFGenFreq = 1 kHz
Settings on the test receiver - D
emodulation: PM
- D
etector: Peak
Measurement On the test receiver measure the resulting phase modulation with
100 kHz lowpass filter and peak analysis.
Frequency modulation
FM deviation setting
Test setup Test setup 1, demodulator mode
Settings on R&S SML /
R&S SMV03
- LEVEL: 0 dBm
- FREQ: 1 GHz
- MODULATION FM FM DEVIATION: 100 kHz
FM SOURCE: LFGen
LFGenFreq = 1 kHz
Settings on the test receiver - D
emodulation: FM
- D
etector: Peak
- Filter: 20 Hz to 23 kHz
(for the moment measurement must still be carried out with 50 Hz /
100 kHz, since filters are not yet implemented)
Measurement Read off the frequency deviation from the test receiver
Note: Since the R&S SML / R&S SMV03 has a purely digital deviation generator, it is adequate
to test its functionality by taking a measurement at one deviation setting and one frequency