Loading...
Sample Setting for First Users R&S®SML / R&S®SMV03
1090.3123.12 E-6 2.2
AM modulation of the output signal
The out
put signal is to be amplitude-modulated next.
- AM modulation depth 10.5 %
- AM signal 3-kHz sine
Operating steps Explanations
.
Modulation
.
MENU / VARIATION
SELECT
MENU / VARIATION
Select menu Modulation using rotary
knob.
Press [SELECT] key or rotary knob.
The submenu is displayed.
.
AM
.
MENU / VARIATION
SELECT
MENU / VARIATION
Select submenu AM.
Press [SELECT] key or rotary knob.
The AM setting menu is displayed.
.
AM Depth
.
MENU / VARIATION
SELECT
MENU / VARIATION
Select parameter AM Depth using
rotary knob.
Press [SELECT] key or rotary knob.
The menu cursor marks the setting
value.
DATA INPUT
x1
ENTER
10
5
.
Enter modulation depth 10.5 % and
acknowledge using [x1/Enter] key.
BACK
Reset menu cursor to AM Depth
using [BACK] key.
.
AM Source
.
MENU / VARIATION
SELECT
MENU / VARIATION
Select AM Source using rotary knob.
Press [SELECT] key or rotary knob.
A pop-up menu displays the current
1-out-of-n selection.