Remote-Control Commands
R&S
®
SMW-K144
199User Manual 1178.8013.02 ─ 06
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:DL:BWP<dir0>:CSIRs:
ZP:SET<gr0>:RES<user0>:BITMap <Bitmap>
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:DL:BWP<dir0>:CSIRs:
NZP:SET<gr0>:RES<user0>:BITMap <Bitmap>, <BitCount>
Sets the location of the ZP CSI-RS in the frequency domain.
Parameters:
<Bitmap> numeric
*RST: #H0
<BitCount> integer
Range: 1 to 12
*RST: 1
Example: See Example "Configuring the CSI-RS settings" on page 155.
Manual operation: See "Bitmap" on page 68
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:DL:BWP<dir0>:CSIRs:
ZP:SET<gr0>:RES<user0>:I0 <I0>
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:DL:BWP<dir0>:CSIRs:
ZP:SET<gr0>:RES<user0>:I1 <I1>
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:DL:BWP<dir0>:CSIRs:
NZP:SET<gr0>:RES<user0>:I0 <I0>
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:DL:BWP<dir0>:CSIRs:
NZP:SET<gr0>:RES<user0>:I1 <I1>
Sets the parameters l
0
and l
1
and define the ZP CSI-RS location relative to the start of
as slot.
Parameters:
<I1> integer
Range: 2 to 12
*RST: 2
Example: See Example "Configuring the CSI-RS settings" on page 155.
Manual operation: See "l0/l1" on page 68
[:SOURce<hw>]:BB:NR5G:UBWP:USER<ch0>:CELL<st0>:DL:BWP<dir0>:CSIRs:
NZP:SET<gr0>:RES<user0>:SCID <ScramblingId>
Sets the parameter n
ID
(scrambling ID).
Parameters:
<ScramblingId> integer
Range: 0 to 1023
*RST: 0
Example: See Example "Configuring the CSI-RS settings" on page 155.
Manual operation: See "Scrambling ID" on page 68