Errors Error messages that may be displayed on the Integral Display, on a 275/375
Handheld Communicator, in AMS, or in the Rosemount Radar Master (RRM)
program, are shown in Table 7-3. Errors normally result in Analog Output
alarm.
Errors are indicated in RRM in the Diagnostics window.
Table 7-3. Error messages.
Message Description Action
RAM Error
An error in the gauge data memory
(RAM) has been detected during the
startup tests. Note: this resets the
gauge automatically.
Contact Emerson Process
Management Service Department.
FPROM Error
An error in the gauge program
memory (FPROM) has been detected
during the startup tests. Note: this
resets the gauge automatically.
Contact Emerson Process
Management Service Department.
HREG Error
An error in the transmitter
configuration memory (EEPROM) has
been detected. The error is either a
checksum error that can be solved by
loading the default database or a
hardware error.
NOTE: the default values are used
until the problem is solved.
Load default database and restart the
transmitter. Contact Emerson
Process Management Service
Department if the problem persists.
MWM Error An error in the microwave module.
Contact Emerson Process
Management Service Department.
Display Error An error in the LCD.
Contact Emerson Process
Management Service Department.
Modem Error Modem hardware failure.
Contact Emerson Process
Management Service Department.
Analog Out Error An error in the Analog Out Module.
Contact Emerson Process
Management Service Department.
Internal Temp Error
An error in the internal temperature
measurement.
Contact Emerson Process
Management Service Department.
Other HW Error
An unspecified hardware error has
been detected.
Contact Emerson Process
Management Service Department.
Meas Error
A serious measurement error has
been detected.
Contact Emerson Process
Management Service Department.
Config Error
At least one configuration parameter
is outside allowed range.
NOTE: the default values are used
until the problem is solved.
• Load the default database and
restart the transmitter (see “Reset
to Factory Settings” on page 7-19)
• Configure the transmitter or upload
a backup configuration file (see
“Backing Up the Transmitter
Configuration” on page 7-15)
• Contact Emerson Process
Management Service Department if
the problem persists
SW Error
An error has been detected in the
transmitter software.
Contact Emerson Process
Management Service Department.