Reference Manual
00809-0100-4026, Rev FA
July 2009
3-13
Rosemount 5400 Series
MOUNTING Mount the transmitter on a nozzle on top of the tank making sure only
qualified personnel perform the installation.
The transmitter housing must not be opened.
If the transmitter housing must be removed for service, make sure that the
PTFE sealing is carefully protected against dust and water.
Cone Antenna Flange
Connection
Figure 3-13. Mounting the 5400
with cone antenna and flange.
1. Place a gasket on top of the tank flange.
2. Lower the transmitter with antenna and
flange into the tank nozzle.
3. Tighten the bolts and nuts with sufficient
torque for the flange and gasket choice.
Transmitter
housing
Bolt
Gasket
Flange
Tank flange
Cone antenna
Nut
Nozzle
Locking screw
(ATEX)
Nut,
60 Nm
(44 Lbft)

Table of Contents