EasyManua.ls Logo

Rosemount 5402 - Nozzle Considerations; 5402 With Cone Antenna; 5402 With Process Seal Antenna

Rosemount 5402
180 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reference Manual
00809-0100-4026, Rev FA
July 2009
3-5
Rosemount 5400 Series
Nozzle Considerations Special considerations may have to be taken because of the nozzle,
depending on the selection of transmitter model and antenna.
5402 with Cone Antenna
The antenna can be recessed in smooth nozzles up to 6 ft (2 m). If the inside
of the nozzle contains disturbing objects, use the extended cone (I).
Figure 3-4. Nozzle
considerations for 5402 with
Cone Antenna.
5402 with Process Seal Antenna
The antenna can be used on nozzles up to 6 ft (2 m), (J). Disturbing objects
inside the nozzle (K) may impact the measurement, and should therefore be
avoided.
The flange on the tank should have a flat or raised face. Other tank flanges
may be possible, please consult your local Emerson Process Management
representative for advice.
Figure 3-5. Nozzle
considerations for 5402 with
Process Seal Antenna.
Spray nozzle
(I)
Smooth nozzle
Bad weldings
(K) Bad welding
(J)