EasyManua.ls Logo

RS PRO IIT-2000 - Page 205

RS PRO IIT-2000
221 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IIT-2000/2010/5000/5010 Instruction Manual/English
05/08/2015 Version No. 001 203
LOW SET:
0.010mA to 1.099mA
00.10mA to 10.99mA
001.0mA to 039.9mA(IIT-5010/5000 is 099.9mA)
Window Comparator Method
Yes
ARC DETECT
Yes
Rise-time Control Function
Yes
RAMP (Ramp Time)
0.1~999.9S
TIMER (Test Time)
OFF
1
, 0.5S~999.9S
GND
ON/OFF
1
The timer can only be turned off under special MANU mode (MANU=***-000).
DC Withstanding Voltage
Output Voltage Range
0.100kV ~ 6.000kV
Output Voltage Resolution
2V
Output Voltage Accuracy
(1% of setting +5V) with no load
Maximum Rated Load
50W (5kV/10mA)[IIT-2000/2010]
100W (5kV/20mA)[IIT-5010/5000]
Maximum Rated Current
10mA [IIT-2000/2010, 20mA [IIT-5010/5000]
0.001mA ~ 2mA (0.100kV≤V≤0.5kV)
0.001mA ~ 10mA (0.5kV<V≤6kV)[IIT-2000/2010]
0.001mA ~ 20mA (0.5kV<V≤6kV)[IIT-5000/5010]
Voltmeter Accuracy
(1% of reading+ 5V)
Voltage Regulation
1% +5V
[Maximum rated load no load]
Current Measurement
Range
0.001mA~010.0mA [IIT-2000/2010]
0.001mA~020.0mA [IIT-5010/5000]

Table of Contents

Related product manuals