Configuration Guide Configuring PoE Configuration
Since the power provided by the PSE covers a cable loss, the power allocated by the power management function is
slightly higher than the maximum power requested by a PD.
By default, the LLDP classification function is enabled and valid only when the auto mode is applied for power
management.
For example, you can run the following commands in turn to enable and then disable LLDP classification:
Ruijie# configure
Ruijie(config)# poe class-lldp enable
Ruijie(config)# no poe class-lldp enable
Ruijie(config)# end
After LLDP classification is enabled, the PD on a port is of Type 1 by default.
Ruijie(config)#show poe interface fastEthernet 0/2
Interface : Fa0/2
Power enabled : enable
Power status : on
Max power : 30.0 W
Allocate power : N/A
Current power : 14.8 W
Average power : 14.7 W
Peak power : 14.8 W
LLDP requested power : 0 W
LLDP allocated power : 0 W
Voltage : 53.5 V
Current : 277 mA
PD class : 4(Type1)
Trouble cause : None
Priority : low
Legacy : off
Power-off time-range : N/A
Power management : auto
Ruijie#show poe interfaces status
Interface Power Power Curr Avg Peak Curr Trouble PD Port
Control Status Power Power Power Current Cause Class Voltage
---------------------------------------------------------------------------
Fa0/1 enable on 15.1W 13.1W 15.1W 284mA 0 0 53.5V
Fa0/2 enable on 14.8W 11.9W 14.8W 277mA 0 4(Type1) 53.5V
Fa0/3 enable on 15.2W 13.3W 15.2W 285mA 0 0 53.5V