Configuration Guide Interface Configuration
Alarm of the low voltage.
Transceiver info
checksum error
Transceiver information checksum error.
Transceiver info I/O
error
Transceiver information read&write error
The following example shows the optical module transceiver diagnosis parameter on the
interface GigabitEthernet 5/4:
Ruijie#show interfaces gigabitEthernet 5/4 transceiver diagnosis
Current diagnostic parameters:
Temp(°C) Voltage(V) Bias(mA) RX power(dBM) TX power(dBM)
36(OK) 3.31(OK) 6.13(OK) -35.64(warning) -5.19(alarm)
The following table shows the optical module transceiver diagnosis parameter:
The diagnostic information for the optical module on
the interface.
Current diagnostic
parameters
Current diagnostic parameters
The diagnostic parameter—temperature, in °C,
correct to 1°C.
The diagnostic parameter—voltage, in V, correct to
0.01 V.
The diagnostic parameter—bias current, in mA,
correct to 0.01 mA.
The diagnostic parameter—RX power, in dBM.
The diagnostic parameter—TX power, in dBM,
correct to 0.01 dBM.
The current state is normal.
The current state is warning.
The current state is alarm.