PDG-DHT8000L Expand Serial Command Functional Specifications
34/101
8.7.3 CF_KEYSTONE Command
Command
“CF_KEYSTONE _%1” [CR]
%1
“UP” ------------- Correct Keystone distortion to reduce upper part of image
“FUP” ----------- Correct Keystone distortion to reduce upper part
“DN” ------------- Correct Keystone distortion to reduce lower part of image
“FDN” ----------- Correct Keystone distortion to reduce lower part largely
“LEFT” ---------- Correct Keystone distortion to reduce left part of image
“FLFT” ---------- Correct Keystone distortion to reduce left part largely
“RIGHT” -------- Correct Keystone distortion to reduce right part of image
“FRGT” --------- Correct Keystone distortion to reduce right part largely
“RST” ------------ Set Keystone OFF
Details
Change level of Keystone distortion correction (Available only in the normal Power
ON status).
When reached the limit of the correction level, projector accepts the command but
does not execute it.
Receiving this command immediately invokes the operation.
When trying to set the value beyond available range, error code “201” is returned
and the operation is not executed.
Example 1: When the correction level of the right part has reached its upper limit
and then the command “RIGHT” is received
Example 2: When the upper part correction allows only another step, and then the
command “FUP” is received.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.7.4 CF_KEYSTONEMODE Command
Command
“CF_KYSTNMODE _%1” [CR]
%1
“STR” --------- Set Keystone store mode to Store
“RST” --------- Set Keystone store mode to Reset
Details Set Keystone store mode (Available only in the normal Power ON status)
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.7.5 CF_CEIL Command
Command
“CF_CEIL_%1” [CR]
%1
“ON” --------------------------- Set Ceiling to ON
“OFF” ------------------------- Set Ceiling to OFF
Details
Set/Cancel Ceiling. (Valid only when in the normal Power ON status.)
When Ceiling is set to ON, image is left/right as well as top/bottom reversed.
The status set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]