8.9.4 CF_MENUSIZE Command
Command
“CF_MENUSIZE_%1” [CR]
%1
“NORMAL” -------------------- Select Menu size to Normal.
“DOUBLE” --------------------- Select Menu size to Double.
Details
Select Menu size. (Valid only when in the normal Power ON status.)
The status set by this command is stored in EEPROM and the setting remains
even after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.5 CF_DISP Command
Command
“CF_DISP_%1” [CR]
%1
“ON” ----------------------------- Set Display to ON
“CNTDWNOFF” -------------- Set Display to Count down Off
“OFF” --------------------------- Set Display to OFF
“UP” --------------- Switch forward (On Count down Off Off On ---)
“DN” --------------- Switch backward (On Off Count down Off On ---)
Details
Set/Cancel Display. (Valid only when in the normal Power ON status.)
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.6 CF_BACKGND Command
Command
“CF_BACKGND_%1 [CR]
%1
“BLUE” -------------------- Select Blue Back
“USER” ------------------- Select User
“BLACK” ------------------ Select Black Back
“UP” ---------- Switch forward (Blue BackUserBlack BackBlue Back)
“DN” --------- Switch backward (Blue BackBlack BackUserBlue Back)
Details
Set Screen status for no signal.(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and the setting remains
even after the power is turned to ALL OFF status.
*When 1=”USER” is received, error code “101” is returned, in the case of
Capture non-practice.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.7 CF_PIP Command
Command
“CF_PIP_%1” [CR]
%1
“OFF” -------------------- Select Off
“USER1” ---------------- Select User1
“USER2” ---------------- Select User2
“USER3” ---------------- Select User3
“USER4” ---------------- Select User4
“USER5” ---------------- Select User5
Details
Set ”Picture in Picture” status.(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and the setting remains
even after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]