PDG-DHT8000L Expand Serial Command Functional Specifications
53/101
8.9.51 CF_FILSCRL Command
Command
“CF_FILSCRL_%1” [CR]
%1 “RST” ---------------------- Reset Filter scroll counter
Details Reset Filter scroll counter
Acceptable Acceptable
Response
Unacceptable
Unacceptable
8.9.52 CF_TESTPAT Command
Command
“CF_TESTPAT_%1” [CR]
%1
“COLOR” ---------------------- Display Color bar
“GRAD1” ---------------------- Display 16step(white→black)
“GRAD2” ---------------------- Display 16step(white←black)
“GRAD3” ---------------------- Display 16step(white↓black)
“GRAD4” ---------------------- Display 16step(white↑black)
“WHITE” ---------------------- Display all white
“BLACK” ---------------------- Display all black
“CROSS” --------------------- Display Cross
“OFF” ---------------------------Do not show test pattern display
“UP” --------------------------- Switch forward
“DN” --------------------------- Switch backward
Details Execute test pattern display.(Available only in the normal Power ON status)
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.53 CF_FDEFAULT Command
Command
“CF_FDEFAULT_%1” [CR]
%1 “RST”
Details
Return the settings to Factory Default status
(Valid only when in the normal Power ON status)
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.54 CF_KEYDIS Command
Command
“CF_KEYDIS_%1” [CR]
%1
“NONE” ------------------------- RC & KEY are valid
“RC” ----------------------------- RC is invalid
“KEY” --------------------------- KEY is invalid
Details Set the limitation of RC/KEY use (Valid only when in the normal Power ON status)
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]