EasyManua.ls Logo

Sanyo PDG-DHT8000L - 8000 Lumens - CR_CLAMP Command; CR_DDOTS Command; CR_DLINE Command

Sanyo PDG-DHT8000L - 8000 Lumens
101 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PDG-DHT8000L Expand Serial Command Functional Specifications
65/101
9.5.5 CR_CLAMP Command
Command
“CR_CLAMP” [CR]
Details Get value of Clamp
Acceptable 000_%1” [CR]
%1 0000” – “ 4095”
Response
Unacceptable
“Error Code” [CR] -------------- When command is invalid in the
given condition (such as being selected input)
?” [CR] --------- When unknown command is received
9.5.6 CR_DDOTS Command
Command
“CR_DDOTS” [CR]
Details Get value of Display Dots
Acceptable 000_%1” [CR]
%1
0256”-”nnnn
(nnnn = Total Dots – Position H)
Response
Unacceptable
“Error Code” [CR] -------------- When command is invalid in the
given condition (such as being selected input)
?” [CR] --------- When unknown command is received
9.5.7 CR_DLINE Command
Command
“CR_DLINE” [CR]
Details Get value of Display Line
Acceptable 000_%1” [CR]
%1
0100” – “ nnnn”
(nnnn = Total Line – Position V)
Response
Unacceptable
“Error Code” [CR] -------------- When command is invalid in the
given condition (such as being selected input)
?” [CR] --------- When unknown command is received

Table of Contents

Related product manuals