EasyManua.ls Logo

Sanyo PDG-DHT8000L - 8000 Lumens - CF_BLENDBLK Command; CF_BLENDBLKALL Command; CF_BLENDTESTPAT Command; CF_BLENDRST Command

Sanyo PDG-DHT8000L - 8000 Lumens
101 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PDG-DHT8000L Expand Serial Command Functional Specifications
44/101
8.9.19 CF_BLENDBLK Command
Command
“CF_BLENDBLK_%1_%2” [CR]
%1
“R” ---------------------- Red
“G” ---------------------- Green
“B” ----------------------- Blue
%2 “-127” ~ 0127”-------------------- Directly specify value of color of %1
Details
Set value of color specified by Edge blending %1.
(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.20 CF_BLENDBLKALL Command
Command
“CF_BLENDBLKALL_%1” [CR]
%1
“UP” ------------------------------- Increment value of Black level(R/G/B) by 1
“DN” ------------------------------ Decrement value of Black level(R/G/B) by 1
Details
Set value of all of Black level of Edge blending.
(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.21 CF_BLENDTESTPAT Command
Command
“CF_BLENDTESTPAT_%1” [CR]
%1
“ON” ---------------------- Set to On
“OFF” -------------------- Set to Off
Details
Set Test pattern of Edge blending.(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.22 CF_BLENDRST Command
Command
“CF_BLENDRST_%1” [CR]
%1 RST” ---------------------- Reset current setting status
Details
Reset current setting status of Edge blending.
(Available only in the normal Power ON status)
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]

Table of Contents