9.10.20 CR_FILTIMER Command
Command
CR_FILTIMER” [CR]
Details Get time to display Filter cleaning / replacement warning on screen
Acceptable “000_%1” [CR]
%1
“1000” ---------------------- Display massage by 1000h used.
“2000” ---------------------- Display massage by 2000h used.
“3000” ---------------------- Display massage by 3000h used.
“OFF” ---------------------- Off(Warning display is not displayed)
Response
Unacceptable
“Error Code” [CR]
9.10.21 CR_FILREMAIN Command
Command
CR_FILREMAIN” [CR]
Details Get remaining number of usable Filter scroll
Acceptable “000_%1” [CR]
%1
“09” = Remaining number of usable Filter scroll : 9 times
“00” = Remaining number of usable Filter scroll : 0 time
Response
Unacceptable
“Error Code” [CR]
9.10.22 CR_TESTPAT Command
Command
CR_TESTPAT [CR]
Details Get setting status of Test pattern
Acceptable “000_%1” [CR]
%1
“COLOR” ---------------------- Color bar is displayed
“GRAD1 ---------------------- 16step(whiteblack) is displayed
“GRAD2 ---------------------- 16step(whiteblack) is displayed
“GRAD3 ---------------------- 16step(whiteblack) is displayed
“GRAD4 ---------------------- 16step(whiteblack) is displayed
“WHITE” ---------------------- All white is displayed
“BLACK” ---------------------- All black is displayed
“CROSS” --------------------- Cross is displayed
“OFF” ---------------------Test pattern display is not displayed
Response
Unacceptable
“Error Code” [CR]
9.10.23 CR_KEYDIS Command
Command
CR_KEYDIS” [CR]
Details Get setting status of RC/KEY use limitation (valid or invalid)
Acceptable “000_%1” [CR]
%1
“NONE” ------------------------- RC & KEY are valid
“RC” ----------------------------- RC is invalid
“KEY” --------------------------- KEY is invalid
Response
Unacceptable
“?” [CR]