PDG-DHT8000L Expand Serial Command Functional Specifications
99/101
9.11.11 CR_OPTCTRLNO Command
Command
“CR_OPTCTRLNO”[CR]
Details Get value of Option control No.
Acceptable “000_%1” [CR]
%1 Four digits of alphanumeric characters
Response
Unacceptable
“?” [CR]
9.11.12 CR_LENSTYPE Command
Command
“CR_LENSTYPE”[CR]
Details Get which type of Lens is currently installed
Acceptable “000_%1” [CR]
%1
Lenstype %1
OnAxisShortFixedLens
LNS‑W52(0.8:1)
ShortZoomLens LNS‑W51(1.2‑1.5:1)
ShortZoomLens LNS‑W50(1.5‑1.8:1)
ShortZoomLens LNS‑W53(1.2‑1.8:1)
StandardZoomLens LNS‑S50(1.8‑2.8:1)
StandardZoomLens LNS‑S51(1.8‑2.8:1)
LongZoomLens LNS‑T50(2.8‑5.0:1)
UltraLongZoomLens LNS‑T51(4.8‑8.0:1)
Response
Unacceptable
“?” [CR]
9.11.13 CR_COLWHEELTYPE Command
Command
“CR_COLWHEELTYPE”[CR]
Details Get which type of Color wheel is currently installed
Acceptable “000_%1” [CR]
%1
“BRIGHTNESS” --- Color wheel for brightness is installed
“COLREPRO” --- Color wheel for color reproduction is installed
Response
Unacceptable
“?” [CR]