PDG-DHT8000L Expand Serial Command Functional Specifications
79/101
9.9.5 CR_INFLAMP Command
Command
“CR_INFLAMP” [CR]
Details Get Lamp mode switching status
Acceptable “000_%1” [CR]
%1
“NML” --------- in Normal status (lamp switching operation is not
active.)
Response
Unacceptable
“?” [CR]
9.9.6 CR_PROJH Command
Command
“CR_PROJH” [CR]
Details Get total running time of projector (in hours)
Acceptable “000_%1” [CR]
%1 “0000000” – “0099999”
Response
Unacceptable “?” [CR]
9.9.7 CR_HMLAMP Command
Command
“CR_HMLAMP” [CR]
Details Get total lamp number
Acceptable “000_%1” [CR]
%1 “002”
Response
Unacceptable
“?” [CR]
9.9.8 CR_LAMPH Command
Command
“CR_LAMPH” [CR]
Details
Get Lamp running time (in hours)
* return actual lamp running time
Acceptable “000_%1_%2_%3_%4” [CR]
%1_%2
%3_%4
Lamp 1 data comes first, and then one space, after that lamp 2
data is followed.
%1 = lamp No.1
%2 = lamp No.2
%3 = lamp No.3
%4 = lamp No.4
※ In the case of 2-lamps model, % 1 and % 2 are only used
(There are no % 3 and % 4)
e.g.; “00410_00410_00410_00410” [CR]
▪▪▪▪ → Lamp No.1 = 410 Hours
Lamp No.2 = 410 Hours
Lamp No.3 = 410 Hours
Lamp No.4 = 410 Hours
Response
Unacceptable
“?” [CR]