8.8 Lamp Command
8.8.1 CF_LAMPMODE Command
Command
“CF_LAMPMODE_%1” [CR]
%1
“FULL” --------------------------- Set lamp mode to 2-lamp (FULL)
“LAMP1” ------------------------- Set lamp1 mode
“LAMP2” ------------------------- Set lamp2 mode
Details
Select Lamp mode. (Valid only when in the normal Power ON status.)
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.8.2 CF_AUTOLAMPCONTRL Command
Command
“CF_AUTOLAMPCONTRL_%1” [CR]
%1
“NORMAL” --------------------- Set lamp control mode to NORMAL
“ECO1” -------------------------- Set lamp control mode to ECO1
“ECO2” -------------------------- Set lamp control mode to ECO2
Details
Select Lamp control mode. (Valid only when in the normal Power ON status.)
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.8.3 CF_LAMPLIFECONTRL Command
Command
“CF_LAMPLIFECONTRL_%1” [CR]
%1
“MODE1” -------------------------- Set Lamp life control mode to Mode1
“MODE2” -------------------------- Set Lamp life control mode to Mode2
Details
Select Lamp life control. (Valid only when in the normal Power ON status.)
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.8.4 CF_LAMPINTERVAL Command
Command
“CF_LAMPINTERVAL_%1” [CR]
%1
“AUTO” ------------------------- Set Lamp interval to Auto
“0024” --------------------------- Set Lamp interval to 24 hours
“0200” --------------------------- Set Lamp interval to 200 hours
“0500” --------------------------- Set Lamp interval to 500 hours
“1000” --------------------------- Set Lamp interval to 1000 hours
“2000” --------------------------- Set Lamp interval to 2000 hours
“OFF” ---------------------------- Set Lamp interval to OFF
Details
Select Lamp interval. (Valid only when in the normal Power ON status.)
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]