PDG-DHT8000L Expand Serial Command Functional Specifications
37/101
8.8 Lamp Command
8.8.1 CF_LAMPMODE Command
Command
CF_LAMPMODE_%1” [CR]
%1
FULL” --------------------------- Set lamp mode to 2-lamp (FULL)
LAMP1” ------------------------- Set lamp1 mode
LAMP2” ------------------------- Set lamp2 mode
Details
Select Lamp mode. (Valid only when in the normal Power ON status.)
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.8.2 CF_AUTOLAMPCONTRL Command
Command
CF_AUTOLAMPCONTRL_%1” [CR]
%1
NORMAL” --------------------- Set lamp control mode to NORMAL
“ECO1” -------------------------- Set lamp control mode to ECO1
“ECO2” -------------------------- Set lamp control mode to ECO2
Details
Select Lamp control mode. (Valid only when in the normal Power ON status.)
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.8.3 CF_LAMPLIFECONTRL Command
Command
CF_LAMPLIFECONTRL_%1” [CR]
%1
MODE1” -------------------------- Set Lamp life control mode to Mode1
MODE2” -------------------------- Set Lamp life control mode to Mode2
Details
Select Lamp life control. (Valid only when in the normal Power ON status.)
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.8.4 CF_LAMPINTERVAL Command
Command
CF_LAMPINTERVAL_%1” [CR]
%1
AUTO ------------------------- Set Lamp interval to Auto
0024” --------------------------- Set Lamp interval to 24 hours
0200” --------------------------- Set Lamp interval to 200 hours
0500” --------------------------- Set Lamp interval to 500 hours
1000” --------------------------- Set Lamp interval to 1000 hours
2000” --------------------------- Set Lamp interval to 2000 hours
OFF” ---------------------------- Set Lamp interval to OFF
Details
Select Lamp interval. (Valid only when in the normal Power ON status.)
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]