EasyManua.ls Logo

Sanyo PDG-DHT8000L - 8000 Lumens - CR_TEMPFAIL Command

Sanyo PDG-DHT8000L - 8000 Lumens
101 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PDG-DHT8000L Expand Serial Command Functional Specifications
97/101
9.11.7 CR_TEMPFAIL Command
Command
CR_TEMPFAIL” [CR]
Details
Get the temperature inside the projector when the abnormal status occurs.
It is possible to get the temperatures for more than one sensor all at once if it is
applicable.
Acceptable “000_%1” [CR]
%1
e.g. “_31.5F”[CR]
_ indicates a space. When the temperature goes under 0, the first
character is “-”, not a space, as in “-05.5F”.
With more than one temperature sensors installed, projector
returns the responses for each sensor in a row.
e.g. “_31.5F_35.2S” [CR]
The first data indicates sensor 1 data, then one space, and
sensor 2 data is followed.
Last character in each data indicates the sensor’s status.
In the abnormal temperature --------------------- “F”
In the safe level of temperature ------------------- “S”
Neither in or close to the abnormal temp. ------- “N
The second example above indicates that the temperature
detected by sensor 1 is 31.5 which means in the abnormal
temperature, and at sensor 2 is 32.5 degrees which is in the safe
temperature.
When the abnormal temperature status is not occurred the data
should be “_00.0S”.
When the projector is reset, “_00.0S is set. Every time
abnormal temperature status is detected, it renews the data and
returns it. It only returns the renewed data of the latest abnormal
temperature and the previous data is cleared.
Response
Unacceptable
“?” [CR]

Table of Contents

Related product manuals