8.7.6 CF_REAR Command
Command
CF_REAR_%1” [CR]
%1
ON --------------------------- Set Rear to ON
OFF” ------------------------- Set Rear to OFF
Details
Set/Cancel Rear. (Valid only when in the normal Power ON status.)
When Rear is set to ON, image is left/right reversed.
The status set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.7.7 CF_VSCALE Command
Command
“CF_VSCALE_%1” [CR]
%1
“035” ---------------------- +35
“031” ---------------------- +31
“001” ---------------------- +1
“000” ---------------------- ±0
01 ---------------------1
31 ---------------------31
32 ---------------------32
“UP” --------------------- Increment setting value of Vscale by 1
“DN” --------------------- Decrement setting value of Vscale by 1
Details
Set Vscale (Available only in the normal Power ON status)
*When selected screen mode is a setting except Custom, return “101[CR] and
the command is not executed.
* When input is no signal, return101” [CR] and the command is not executed.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.7.8 CF_VPOS Command
Command
“CF_VPOS_%1” [CR]
%1
“015” --------------------- +15
“014” --------------------- +14
“001” --------------------- +1
“000” --------------------- ±0
01 ---------------------1
14 ---------------------14
15 ---------------------15
“UP” --------------------- Increment setting value of Vposition by 1
“DN” --------------------- Decrement setting value of Vposition by 1
Details
Set V Position (Available only in the normal Power ON status)
*When selected screen mode is a setting except Custom, return “101” [CR] and
the command is not executed.
* When input is no signal, return101” [CR] and the command is not executed.
Acceptable “000” [CR]
Response
Unacceptable
“Error Code” [CR]