Commissioning with Terminal PR 5610 Installation Manual
118 Sartorius
5.3 Weighing point mask
Calling up mask
Weighingpoint
is done from the
Main Command Level
by pressing key [W].
PR1713 Rel. 03.12 20.05.2004 09:05
Weighingpoint
Max= 3000kg e= 0001kg
A < > N 0050kg
Max= 3000kg e= 0001kg
B < > N 0330kg
Max= 6000kg e= 0002kg
AB< > N 0380kg
Keys
0 Set Zero I/O Tare In/Out
Select Display T Tare G Gross N Net ? Test F Flow Z Zeroset D Diff S Setp
P Print C Calib/Config A Assign weighingpoints E Exit
The functions of this mask are:
Weight display and function keys for the weighing points
Calling up sub-menus/ masks:
calibration / configuration
Calib/Config
weighing point assignment
Assign weighingpoints
Return to the main menu is with [E]
Exit.
Weight display and function keys for the weighing points.
Weighing point selection (A, B or AB) is by means of the cursor up and down keys. The actually selected weighing
point is highlighted by inverse display.
If a physical weighing point has been assigned to e.g. WP B, but does not deliver valid weight data, it is
displayed as follows:
Max= 3000kg e= 0001kg
B Err 9:nocom
The function keys relate to the instantaneously selected weighing point.
Mask description.
Gross/ net/ tare weight display
G/N/T Select Display
The gross, net or tare weight can be displayed by pressing the relevant key with the scale tared. This is shown by
display of the relevant letter.
Setting the zero is done with key [0]
Set Zero
When the scale was set to zero, >0< is displayed in front of the weight.
Setting or erasing the tare memory is done with keys [I] or [O]
I/O Tare In/Out
Press key [?] to carry out the analog test
? Test
. Test value and reply line
Toggle Testmode Status OK
instead of
the weight is displayed. Pressing key [?] once more displays the previous value again.
Pressing key [P]
Print
prints out the weight values on the printer port.
Calling up mask
Assign weighing points
is done by pressing key [A]. If a production is running, this call is disabled,
message:
Production is active, no configuration possible