Commissioning with Terminal PR 5610 Installation Manual
114 Sartorius
5.2.4 Entry of software licence numbers
Calling up mask
License configuration
is done from sub-menu
Configuration
by pressing key [L].
PR1713 Rel. 03.12 20.05.2004 09:05
License Configuration Mo 05.July 2004 09:31:51
Boardnumber: 8409060
S88 Disabled PR1713/20 Single component batching Disabled
PR1713/21 Multi component batching Disabled
A Add a License PR1713/30 Standard batching phases (Disabled)
PR1713/31 Open communication Disabled
D Delete a PR1713/32 S88 Phase Batching Disabled
PR1713/OB Onboard weighing Disabled
PR1713/SM SMS Messaging Disabled
PR1713/AL ALIBI Disabled
P Print License PR1740/11 Production control and superv.Disabled
PR1740/21 Production plan Disabled
PR1740/31 DDE transfer Disabled
PR1740/41 PR1740 Remote control Disabled
PR1781/13 Phase configuration (Disabled)
PR1791/13 DDE Server communication Disabled
PR1792/13 OPC Server communication Disabled
E Exit PR1792/20 OPC database access Disabled
The licence numbers to be entered must refer to the board number displayed on top of the mask.
The status of all licences is displayed:
enabled
or
disabled.
Licences which cannot be used are indicated in
parenthesis (e.g. depending on S88 status).
Editing function
A Add a License
D Delete a License
P Print License
E Exit
After pressing the relevant key ([A] or [D]), the system prompts for entry of a licence number:
Enter License
number: _
The system checks the licence number. Unless it is accepted by the system, message:
Not a License number
or:
Wrong License number
is displayed.
If the licence number is unknown, delete the wrong licence number with the backspace key and terminate
the entry with return key.