Commissioning with Terminal PR 5610 Installation Manual
146 Sartorius
5.8 IEC 61131 operating level
The operating level is required for testing (user-specific) IEC 61131 programs.
Calling up Commandline operating level is done from the Main-Command-Level by pressing key [L].
• An empty screen with prompt character '
>
' is displayed.
The cursor is positioned behing character '
>
'.
The operating level expects the entry of a command.
• By entry of command
Help
(complete by pressing the Enter key [↵]), a short-form description of possible
commands is displayed.
Subsequently, the system waits again for entry of a command:
>help
DIR [FB|FU|PG] [OPER|PLC|REC]
SHOW TASK [OPER|PLC|REC] [/STATUS][/TIME][/CONT]
SHOW TABLES [<dbase_name>]
SHOW TOPCPU
EXIT
KILL <OPER|PLC|REC> <1|2|3|4|ALL>
RESTART <OPER|PLC> <1|2|3|4|ALL>
DELETE <dbase_name>
[@] <program_name> [/NOBREAK]
>_
Leaving the IEC 61131 operating level
• By entry of command
Exit
(complete by pressing the Enter key [↵]), return is to the Main-Command-Level.