11
Process data description
MOVIPRO® SDC process sequence
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
120
11.2.3 Digital inputs and outputs
The input/output bytes of the device for 12DI/4DIO (digital inputs/digital outputs) are
defined as follows:
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Digital outputs
MOVIPRO
®
Fieldbus master
Digital inputs
17986358283
Digital inputs (DI)
Digital inputs (2bytes)
Bit Meaning
0 Digital input DI00 / status digital output DO00
1 Digital input DI01 / status digital output DO01
2 Digital input DI02 / status digital output DO02
3 Digital input DI03 / status digital output DO03
4 Digital input DI04
5 Digital input DI05
6 Digital input DI06
7 Digital input DI07
8 Digital input DI08
9 Digital input DI09
10 Digital input DI10
11 Digital input DI11
12 Digital input DI12
13 Digital input DI13
14 Digital input DI14
15 Digital input DI15
Digital outputs (DO)
Digital outputs (1byte)
Bit Meaning
0 Digital output DO 00
1 Digital output DO 01
2 Digital output DO 02
3 Digital output DO 03
4–15 Reserved = 0
16998413/EN – 12/2016