13
Parameter setting
Parameterizing the communication and control unit "PFH-..."
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
174
13.4 Parameterizing the communication and control unit "PFH-..."
INFORMATION
To be able to replace the device quickly, save the device data to the SD memory
card following successful startup (data management).
13.4.1 Factory installed gateway program
In order to simplify the startup, MOVIPRO
®
ADC is delivered with a preinstalled gate-
way program. This allows MOVIPRO
®
ADC to be operated after startup of the en-
coder/motor, the IPOS
PLUS®
application modules that are used and the fieldbus. Addi-
tional parameterizations with the Application Configurator controller software are not
required in this case.
If you would like to use special MOVIPRO
®
ADC features such as CCU application
modules, R15regenerative power supply or external slaves, however, you must carry
out a CCU startup in the Application Configurator controller software.
13.4.2 MOVIPRO
®
ADC as parameterizable device (CCU)
You can parameterize MOVIPRO
®
ADC with the Application Configurator controller
software. The Application Configurator is part of the
MOVITOOLS
®
MotionStudioengineering software.
Start application configurator
WARNING
Risk of crushing from uncontrolled start-up of the motor, if the start-up is aborted due
to using an inadmissible version of the MOVITOOLS
®
MotionStudio engineering
software.
Severe or fatal injuries.
Always use MOVITOOLS
®
MotionStudio V6.20version or later.
Proceed as follows:
ü You have installed the MOVITOOLS
®
MotionStudio engineering software on the
engineering PC, V6.20 or later.
16998413/EN – 12/2016