Configuration and startup of Modbus/TCP
Configuration of the Modbus/TCP master
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
92
8.2.2 Setting Ethernet component
Proceed as follows:
1. Open the hardware configurator in PL7PRO.
2. Double-click on the Ethernet component (in this case: ETY4103).
ð The configuration window is displayed.
18014399339035147
3. If you have a non-expandable rack, enter the value "1" in the edit box [2].
4. Enter the number of the slot that the Ethernet component is plugged into in edit
box [3] (here: 4).
ð In this example, the XWAY address is 1.4.
5. Activate the radio button [5].
6. Enter the IP address and the network parameters into the edit boxes [6].
7. If the PLC receives the address parameters via DHCP, activate the radio button
[7].
8. Activate the radio button [8].
9. Activate the check box [4].