6
Configuration and startup of EtherNet/IP™
Configuration of the EtherNet/IP™ master
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
43
6.2.2 Configuration with RSLogix 5000 as of version V20
The following example describes configuration of the Allen Bradley controller Control-
Logix 1756_L71 with Studio 5000 Logix Designer, version V24 (up to Version V20:
RSLogix 5000).
For the Ethernet communication, a 1756-EN2TR EtherNet/IP™ interface is used.
Proceed as follows:
1. Start Studio 5000 Logix Designer and select the view "Controller Organizer" (tree
structure on left part of the window).
2. Select the EtherNet/IP™ interface (1756-EN2TR in this case) in the folder "I/O
configuration".
3. Select the command [New Module] from the context menu.
ð A module catalog is displayed.
16759271947
4. Enter "Movipro" in the search field [1] and press the <Enter> key.
ð If the EDS file was installed correctly, the device is displayed in the catalog.
5. Select the entry "SEW MOVIPRO" [2].
16998413/EN – 12/2016