13.7.8 Parameter group 8: Device functions
Specific device functions are defined with this parameter group.
P80. Setup
P802 Factory setting
Setting range: No / standard / delivery state
Reestablishes the factory setting for the parameter saved in EEPROM.
INFORMATION
Before you reset the parameter, save the set parameter values with the
MOVITOOLS
®
MotionStudio engineering software. After the reset, you must readjust
the parameter values and terminal assignments in accordance with the requirements.
"Standard" setting: nearly all parameter values are overwritten. The following data
is not reset:
Application module
Fault memory
Statistical data
P20. Speed control (→2199)
P210 P gain hold controller (→2201)
P30./ P31. Limits1/2 (→2202)
P32./P33. Motor compensation1/2 (→2203)
P344 Interval for motor protection (→2207)
P345/346 IN/UL monitoring1/2 (→2208)
P53. Motor temperature protection (→2211)
P70. Operating modes (→2216)
P73. Brake function (→2219)
P905 Hiperface offset (motor) (→2234)
P910 Gain X controller (→2234)
P94. IPOS encoder (→2239)
Setting "Delivery state": All parameter values are overwritten.
The 7-segment display of the device shows the status "8.8.8" during the reset. When
the reset is complete, the previous operating state of the device appears in the 7-seg-
ment display. The parameter automatically returns to the "no" setting.