13.7 Parameter descriptions
Observe the following:
• The parameter descriptions are divided into 10parameter groups.
• The parameter names correspond to their representation in the parameter tree.
• The following symbols are used in the parameter descriptions:
Parameters which are switch-selectable and available in parameter sets1 and
2.
Parameters which can be changed only in inverter status "Inhibited" (output
stage at high resistance).
Parameters which are automatically changed by the startup function.
13.7.1 Parameter group 0: Display values
This parameter group contains the following information:
• Process values and states of the basic device
• Process values and states of the installed options
• Fault memory
• Fieldbus parameters
P00. Process values
P000 Speed
Resolution: ±0.2min
-1
The speed is determined by taking the setpoint speed and the set slip compensation
in VFC or V/f mode without an encoder connection. The speed is established from the
encoder or resolver signals and is displayed when there is an encoder connection.
P001 User display
Determined by the following parameters:
• P850 Scaling factor numerator (→2228)
• P851 Scaling factor denominator (→2228)
• P852 User unit (→2228)
P002 Frequency
Output frequency of the device (signed)
P003 Actual position
With encoder connection, position of the drive as a value in increments observing the
signs in the range 0–±(2
31
-1) increments (with encoder connection. Without encoder
connection, the value is zero.
P004 Output current
Apparent current in the range 0–200% of the nominal device current I