13
Parameter setting
"PFA-..." power section parameter overview
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
185
13.6 "PFA-..." power section parameter overview
The following table shows an overview of all parameters:
• Factory setting values are in bold.
• Numerical values are displayed with the complete setting range.
0.. Display values
00. Process values
No. Name Range/factory setting
000 Speed –
001 User display –
002 Frequency –
003 Actual position 0–±(2
31
-1) Increments
004 Output current 0 – 200% I
N
005 Active current 0 – 200% I
N
006/007 Motor utilization 1/2 0–200%
008 DC link voltage –
009 Output current –
0.. Display values
01. Status displays
No. Name Range/factory setting
010 Inverter status –
011 Operating status –
012 Error status –
013 Current parameter set –
014 Cooling air temperature -40–125°C
015 Operating hours –
016 Enable hours –
017 Work –
018/019 KTY utilization1/2 –
0.. Display values
02. Analog setpoints
No. Name Range/factory setting
020 Analog input AI1 -10–+10V
0.. Display values
03. Digital inputs of basic device
No. Name Range/factory setting
030 Digital input DI00 –
032–035 Digital inputs DI02–DI05 –
0.. Display values
05. Digital outputs basic device
No. Name Range/factory setting
050 Digital output DB00 –
0.. Display values
07. Device data
No. Name Range/factory setting
070 Device type –
071 Nominal output current –
072 Encoder slot option/firmware –
076 Basic device firmware –
078 Technology function –
079 Device variant –
16998413/EN – 12/2016