14.3.1 Ethernet service interface
The Ethernet service interface connects the device with an engineering PC for config-
uration and maintenance purposes.
Tools required
Wrench with wrench size 8
Required material
Ethernet cables with RJ45 plug connectors
Connecting the engineering PC with the Ethernet service interface
1. Remove the screw plug using the wrench.
2. Plug an RJ45 plug connector of the Ethernet cable into the Ethernet service inter-
face.
3. Plug the other RJ45 plug connector of the Ethernet cable into the Ethernet service
interface of the engineering PC.
Addresses
Standard IP address: 192.168.10.4
Subnet mask: 255.255.255.0