7
Ethernet Industrial Protocol (EtherNet/IP™)
Return codes for parameterization via "explicit messages"
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
88
7.5.2 MOVILINK
®
-specific return codes
The following table shows the MOVILINK
®
-specific return codes (MOVILINK
®
"Error
Class" and "Additional Code") in the event of an incorrect parameterization:
MOVILINK
®
Designation
Error class Additional code
0x05
0x00 Unknown error
0x01 Illegal Service
0x02 No Response
0x03 Different Address
0x04 Different Type
0x05 Different Index
0x06 Different Service
0x07 Different Channel
0x08 Different Block
0x09 No Scope Data
0x0A Illegal Length
0x0B Illegal Address
0x0C Illegal Pointer
0x0D Not enough memory
0x0E System Error
0x0F Communication does not exist
0x10 Communication not initialized
0x11 Mouse conflict
0x12 Illegal Bus
0x13 FCS Error
0x14 PB Init
0x15 SBus - Illegal Fragment Count
0x16 SBus - Illegal Fragment Type
0x17 Access denied
– Not used
0x08
0x00 No Error
0x10 Illegal Index
0x11 Not yet implemented
0x12 Read only
0x13 Parameter Blocking
0x14 Setup runs
0x15 Value too large
0x16 Value too small
0x17 Required Hardware does not exist
0x18 Internal error
0x19 Reserved
0x1A Reserved
0x1B Parameter protected
0x1C "Controller inhibit" required
0x1D Value invalid
0x1E Setup started
0x1F Buffer overflow
0x20 "No enable" required
0x21 End of File
0x22 Communication Order
0x23 "IPOS Stop" Required
0x24 Autosetup
0x25 Encoder Nameplate Error
0x29 PLC State Error
16998413/EN – 12/2016